Technologische Studien

Volume 7/2010Special issue "Preventive Conservation"

Content

Entwicklung und Austestung von Standard-Kunststoff-Verpackungslösungen für Sammlungs- & Museumsdepots

Martina Grießer, Michael Krainz, Johannes Bergmair, Silvia Kalabis, Martina Griesser-Stermscheg, Marianne Novotny-Kargl, Regina Knaller, Andrea Hanzal, Josef Bailer, Christiane Jordan, Wolfgang Werther, Erich R. Schmid, Elisabeth Schlegel, Ute Kannengiesser, Stefanie Jahn and Ernst Gregor

From 2005–2009, the Kunsthistorisches Museum, in collaboration with the Essl Museum, the Wien Museum, the University of Applied Arts, Vienna, and the Federal Office for the Care of Monuments, in cooperation with the Austrian Research Institute for Chemistry and Technology (Österreichischen For schungsinstitut für Chemie & Technik, ofi) and with financial support from the Austrian Research Promotion Agency Ltd. (Forschungsförderungsgesellschaft, FFG), conducted a research project for the further development of plastic packing solutions for collections and museums.

Building on experiences from an earlier project, primarily those transparent plastic films available in Austria and southern Germany were to be better characterised, and guidelines for packing developed through practical experiments, also applicable for objects from small collections that are sometimes unable to employ trained conservators.

The present article describes the experiments and investigations carried out at the participating institutions and summarises the most important findings for the short-term packing for pest control using nitrogen gas and the long-term storage in plastic bags with or without a nitrogen atmosphere for a storage period of more than one year. The packing experiments encompassed a wide variety of objects, from individual, small, easily handled (art) works – such as metal jewellery, bathing caps, or ethnographic objects – to large-format pictures, to entire holdings of coaches or paintings as well as a church pulpit. For anoxic disinfestation with nitrogen gas, the use of barrier films is necessary; primarily the EVOH films have been shown to be suitable. For simple long-term packing, commercially readily available (and affordable) PE film (free of plasticizers and harmful substances) can normally be used; for more rigorous conditions, barrier films (EVOH) must again be employed.

Additional adsorber or absorber materials can usually be omitted from the packages – with the exception of a few special cases. Likewise, in the tests conducted here, oxygen-free packing in a nitrogen atmosphere showed no advantages for the preservation of the objects versus packing under ambient conditions. The most important factors during the packing process are the environmental conditions, as the exterior environment is effectively “packed inside,” and unfavourable packing conditions can lead to problems in climate adjustment within the packages.

Die „Kustodische Großreinigung unter RestauratorInnenaufsicht“.
Präventiv konservatorische Ensemblepflege in historischen Prunkräumen an den Beispielen der Kaiserappartements, des Sisi Museum und der Historischen Silberkam

Christina Schaaf-Fundneider, Eva Hottenroth and Olivia Lichtscheidl

The present article provides insight into the execution of “large-scale custodial cleaning under conservation supervision” in the historic state rooms of the Vienna Hofburg, which are administered by the Schloss Schönbrunn Kultur- und Betriebsges.m.b.H. (SKB). Under
the direction of a team of conservators, the appointments, consisting of both movable objects and immobile furnishings, were cleaned and maintained, in cooperation with the in-house cleaning staff.

The team of conservators “Atelier Kunstgenuss,” under the direction of Christina Schaaf-Fundneider and Eva Hottenroth, was entrusted with this task in 2008, 2009, and 2010. Large-scale custodial cleaning is understood as a preventive conservation measure for the room shells, the entire historic interior, and the objects in the Sisi Museum. The removal of superficially accumulated or adhered dust and potentially damaging deposits, introduced in part through the numerous visitors, is an important element in the measures undertaken. Further emphases include the monitoring of the state of preservation of the rooms and furnishings, and the preparation of a resulting overall concept for the planning of all pending conservation measures. Large, expensive restorations are thus, if not completely circumvented, at least significantly postponed. The condition surveying of all objects enables and simplifies effective planning of future conservation work and budgeting.

The administration of the SKB is an Austria-wide forerunner with its “large-scale custodial cleaning” project, and an example for other institutions of this type.

Computergestützte Gebäudesimulation als effiziente Entscheidungshilfe bei komplexen thermischen Sanierungsvorhaben

Klaus Kreč und Alfons Huber

Through the privatization of previously centrally administered federal or state institutions, it has become more difficult to execute effective long-term refurbishment measures aimed at increasing energy efficiency: this is particularly the case when several different users rent space within a single building.

It is especially problematic when individual users demand differing environmental standards, or when one tenant ascertains structural deficiencies or shortcomings in the be haviour of other users that negatively affect their own operating procedures, the causes of which, however, lie outside of the respective administrative areas of each. In such a situation, it is prudent to first predict the efficacy of proposed measures by means of a thermal building simulation using dedicated computer programs.

In the case of the Collection of Ancient Musical Instruments (Sammlung alter Musikinstrumente, SAM), room temperatures of over 30 °C had for years repeatedly been reached in the summer, although very effective light protection methods had been implemented in the past. The computer simulation provided, among other findings, the evidence that the temperatures of over 31 °C in the offices of the Austrian National Library (ÖNB) in the 2nd floor could be lowered to 26 °C through exterior shading, the installation of isolation glazing on the inner window casements, and controlled air exchange. It was further shown that the reactivation of the original ventilation system requested by the
SAM since 1988 to maintain usability during summer heat waves (max 27 °C by ÖNorm B8110-3) is unavoidable; this is only possible, however, on the precondition that the neighbouring users also install adequate shading and controlled ventilation. A proposed exterior shading of the large windows on the raised ground floor through planters placed on the terrace would effect a significant reduction in direct sun exposure through the windows there.

The insulation of the ceiling between the uppermost floor and the attic, made possible by a sponsor of the SAM, has in deepest winter yielded a c. 30 % savings in heating costs for the ÖNB offices.

Symptome bekämpfen oder Ursachen vermeiden?
Die „Kalte Wand“ in Museen, Depots und Kirchen – ein oft unterschätztes Phänomen in historischen (und auch in neuen) Gebäuden

Jochen Käferhaus und Alfons Huber

In den Jahren 1989 bis 1992 wurde die Gemäldegalerie des KHM einer Generalsanierung unterzogen. Die damals von den RestauratorInnen des KHM geforderte Bauteiltemperierung zur nachhaltigen Vermeidung des „Kalte-Wand-Problems“ und der damit verbundenen Gefahr der Schimmelbildung wurde nicht realisiert und stattdessen wurde – unter Beibehaltung der raumzentralen Radiatorgruppen – eine konventionelle Klimaanlage installiert. Nachdem 2006 in Saal IV der Gemäldegalerie erneut aktiver Schimmelbefall an den kalten Außenwandecken festgestellt wurde, bestand die Möglichkeit, diesmal den „richtigen“ Lösungsansatz zu verfolgen.

Der Beitrag diskutiert nochmals das prinzipiell falsche Konzept von Luftheizungssystemen und der Klimatisierung über zentrale Lüftungsanlagen. Es werden die realisierten, technisch signifikant einfachen Maßnahmen zur Temperierung der Außenwand beschrieben und die Ergebnisse nach der ersten Heizperiode ausgewertet. Dabei bestätigt sich nicht nur die prognostizierte Konstanz des Klimaverlaufes; gegenüber dem Mittelwert des spezifischen Heizwärmeverbrauchs des Museums konnte mittels Wärmemengenzähler auch ein um 30 % verringerter spezifischer Wärmebedarf festgestellt werden.

Auf der Suche nach der richtigen Entscheidung.
Thermographie, Dichtigkeitsmessungen und Pilotanlage im Vorfeld thermischer Sanierung

Alfons Huber, Azra Korjenic und Thomas Bednar

Ein Jahrzehnt nach Einsatz der sog. „Museumsmilliarde“ zur Sanierung der österreichischen Bundesmuseen zeigt sich, dass die in den Sanierungskonzepten definierten klimatischen Rahmenbedingungen zur „Präventiven Konservierung“ nicht zuverlässig erfüllt werden können und, vor allem auf dem Gebiet der thermischen Sanierung, weitere Maßnahmen ergriffen werden müssen. Eine Erhöhung der Klimakonstanz ist nur über einen kontrollierten Luftwechsel möglich; Voraussetzung dafür ist allerdings ein Nachdichten der Gebäudehülle, womit gleichzeitig die Heizenergieverluste verringert werden können.

Der Beitrag untersucht mittels Blower Door Test und Thermographieaufnahmen einfache Maßnahmen zur Optimierung bereits sanierter großformatiger Fenster und Balkontüren im denkmalgeschützten Altbau, wodurch deren Wärmedurchgang sowie die Lüftungswärmeverluste um weitere 25% gesenkt werden können.

In einem zweiten Pilotprojekt wird die Möglichkeit zur Umrüstung einer bestehenden Radiatorheizung auf Bauteiltemperierung (d. i. das Heizsystem mit dem geringsten konservatorischen Schadenspotential) mittels Sockelheizleiste untersucht und der Wärmebedarf der Wärmeabgabegeräte (Radiator bzw. Sockelheizleiste) mittels Wärmemengenzähler erfasst. Neben der signifikant verbesserten Klimakonstanz konnte auch ein deutlich verringerter Nachbefeuchtungsbedarf sowie ein im Volllastbetrieb um ca. 25 – 30% verringerter Heizwärmebedarf nachgewiesen werden. In der Übergangszeit ab Mitte April lag (wegen des Heizens bei offenem Fenster) der Mehrverbrauch der Radiatoren zwischen 50 und 100 %. Am Ende des Messzeitraumes betrug die von den Radiatoren abgegebene Wärmemenge mehr als das Doppelte von derjenigen der Sockelheizleiste. Bei Gebäuden mit in den Außenwänden verlegten Steigsträngen einer durchgehend betriebenen Zentralheizung wird eine Vorlaufsteuerung über Bauteilfühler (statt Außenluftfühler) empfohlen.

Die beiden Pilotprojekte schaffen Entscheidungssicherheit für die Sinnhaftigkeit der Nachsanierung von großformatigen Fenstern und Türen sowie für die Umrüstung von Radiatorheizung auf Bauteiltemperierung.